| Symptoms |
Causes |
Solutions |
| Low
Flow |
Soot
building up in piping to furnace |
Clean
pipes, particularly the elbows |
| Firecheck
screen is dirty |
Clean
or replace screen |
| Air
filter is dirty |
Clean
or replace air filter |
| Excessive
soot buildup in retort |
Use
burnout procedure to remove excessive soot. If
extreme sooting, replace catalyst |
| Pump
motor drive belts slipping |
Tighten
belts |
| Pump
by-pass regulator allowing too much flow around pump |
Adjust
regulator to limit flow by-pass. Make sure pump
motor amps are not excessive. |
| Flowmeters
not reading correctly |
Inspect
and clean flowmeters. Verify that the float serial number
matches the flowmeter body. Verify float weights are
not missing. |
| High
Dewpoint |
Air/Gas
ratio too high |
Reduce
air/gas ratio to lower dewpoint |
| Excessive
soot buildup in retort |
Use
burnout procedure to remove excessive soot in the retort |
| Breeched
retort |
Replace
retort |
| Low
Dewpoint |
Air/Gas
ratio too low |
Increase
air/gas ratio to raise dewpoint |
| Methane
carryover in process gas |
Use
burnout procedure to remove excessive soot. If
extreme sooting, replace catalyst. |
| Mixture
pump won't run |
Holdback
temperature not achieved |
Allow
generator to reach minimum temperature for proper
operation |
| Pump
motor starter tripped |
Reset
motor starter and monitor pump amp draw |
| Firecheck
switch tripped |
Reset
firecheck |
| High/low
gas pressure switches of mixture pressure not made |
If
pressure is correct at switch locations, adjust or replace
switch |
| Excessive
sooting |
Low
temperature in retort |
Verify
control thermocouple and instrument are working properly |
| Air/gas
ratio too low |
Raise
air/gas ratio slightly |
| Quality
of supply gas suspect |
Have
supply gas checked for additives |
| Catalyst
depleted |
Replace
catalyst |
| Generator
will not reach operating temperature (gas-fired) |
Dirty
combustion air filter |
Clean/replace
combustion air filter |
| Burner
air/gas settings not correct |
Adjust
air/gas settings per combustion drawing |
| Control
thermocouple failure |
Replace
control thermocouple |
| Generator
will not reach operating temperature (electrically heated) |
SCR/contactor
not working properly |
Adjust/replace
SCR/contactor |
| Power
not on or fuses blown |
Turn
on power, replace fuses |
| Heating
element(s) failed |
Replace
heating elements |